Overhead insulated cable is a special cable used in overhead power lines, with insulation layer and sheath. Compared to bare wires, it significantly improves power supply safety and reliability, effectively preventing short circuits, external interference, and personal electric shock. Its insulation material is usually weather resistant polyethylene or cross-linked polyethylene, suitable for areas with limited space or environmental sensitivity such as urban power grids and forest areas.
Model: JKLGYJ-10kV 185-25
| Product Parameters: |
|
Rated Voltage: 10 kV Conductor Material: Aluminum conductor (stranded) with steel core Conductor Cross-Section: Aluminum 185 mm² / Steel core 25 mm² Insulation Material: Silane cross-linked polyethylene (XLPE) Insulation Thickness: 3.4 mm Temperature Resistance Range: Conductor temperature ≤ 90℃for long-term operation; ≤ 250℃ for short circuits (≤ 5 seconds); adaptable to outdoor environments of -40℃ ~ 40℃ Laying Requirements: Complies with 10 kV aerial cable specifications. Avoid high-temperature and corrosive areas. Minimum bending radius ≥ 20 × cable outer diameter. Use dedicated insulated clamps for outdoor fixation; leverage the steel core's properties to ensure erection stability. |
| Technical Standards: |
| GB/T14049-2008 |
Model: JKLYJ-10kV 1X50
| Product Parameters: |
|
Rated Voltage: 10 kV Conductor Material: Aluminum conductor (stranded) Conductor Cross-Section: 1 core × 50 mm² Insulation Material: Silane cross-linked polyethylene (XLPE) Insulation Thickness: 3.4 mm Temperature Resistance Range: Normal operating temperature -40℃to 90℃; withstands 250℃ for short circuits (maximum duration 5 seconds) Laying Requirements: The bending radius of the cable shall not be less than 12 times the cable outer diameter. |
| Technical Standards: |
| GB/T14049-2008 |
Model: JKLYJ-10kV 1X300
| Product Parameters: |
|
Rated Voltage: 10 kV Conductor Material: Aluminum conductor (stranded) Conductor Cross-Section: 1 core × 300 mm² Insulation Material: Silane cross-linked polyethylene (XLPE) Insulation Thickness: 3.4 mm Temperature Resistance Range: Long-term operation ≤ 90℃; short circuit (≤5 seconds) ≤ 250℃; outdoor adaptation range -40℃ ~ 40℃ Laying Requirements: Complies with 10 kV aerial cable standards. Avoid high-temperature and corrosive environments. Minimum bending radius ≥ 20 × cable outer diameter. Use dedicated insulated clamps. |
| Technical Standards: |
| GB/T14049-2008 |
Model: JKLYJ-10kV 1X240
| Product Parameters: |
|
Rated Voltage: 10 kV Conductor Material: Aluminum conductor (stranded) Conductor Cross-Section: 1 core × 240 mm² Insulation Material: Silane cross-linked polyethylene (XLPE) Insulation Thickness: 3.4 mm Temperature Resistance Range: Conductor temperature ≤ 90℃for long-term operation; ≤ 250℃ for short circuits (≤ 5 seconds); outdoor ambient temperature adaptation range: -40℃ ~ 40℃ Laying Requirements: Complies with 10 kV aerial cable specifications. Avoid high-temperature and corrosive environments. Minimum bending radius ≥ 20 × cable outer diameter. Use dedicated insulated clamps for outdoor fixation. |
| Technical Standards: |
| GB/T14049-2008 |
Model: JKLYJ-1kV 1X240
| Product Parameters: |
|
Rated Voltage: 1 kV Conductor Material: Aluminum conductor (stranded) Conductor Cross-Section: 1 core × 240 mm² Insulation Material: Silane cross-linked polyethylene (XLPE) Insulation Thickness: 2.2 mm Temperature Resistance Range: Normal operating temperature: -40℃to 90℃; withstands 250℃ during short circuits (maximum duration: 5 seconds) Laying Requirements: Suitable only for outdoor aerial installation. During erection, safety distances from the ground, buildings, and trees must be maintained (e.g., minimum distance of 6 meters from the ground in residential areas), and the parallel laying spacing between cables shall not be less than 0.1 meters. |
| Technical Standards: |
| GB/T12527-2008 |
Model: JKLYJ-1kV 1X400
| Product Parameters: |
|
Rated Voltage: 1 kV Conductor Material: Aluminum conductor (stranded) Conductor Cross-Section: 1 core × 400 mm² Insulation Material: Silane cross-linked polyethylene (XLPE) Insulation Thickness: 2.2 mm Temperature Resistance Range: Conductor temperature ≤ 90℃for long-term operation; ≤ 250℃ for short circuits (≤ 5 seconds); adaptable to outdoor environments of -40℃ ~ 40℃ Laying Requirements: Must comply with outdoor aerial cable installation specifications |
| Technical Standards: |
| GB/T12527-2008 |