Contact Us
PVC insulated power cables use polyvinyl chloride as the insulation layer, which has excellent electrical insulation performance and mechanical protection capability. It has a stable structure, oil resistance, corrosion resistance, good flame retardant performance, and is safe and reliable. Widely used for fixed installation on transmission and distribution lines with rated power frequency of 0.6/1kV and below, transmitting and distributing electrical energy, commonly found in urban power grids, building internal power supply, and various power engineering projects.
Model: VV-0.6/1kV 3x95+1x50
| Product Parameters: |
|
Rated Voltage: 0.6/1 kV Conductor Material: Copper conductor (stranded) Conductor Cross-Section: 3 cores × 95 mm² + 1 core × 50 mm² Insulation Material: Polyvinyl chloride (PVC) Insulation Thickness: 1.6 mm for 95 mm² cores; 1.4 mm for 50 mm² core Sheath Material: Polyvinyl chloride (PVC) Sheath Thickness: 2.2 mm Temperature Resistance Range: -20℃ to 70℃ (normal operation) Short-Circuit Withstand Temperature: 160℃ (maximum duration ≤ 5 seconds) Laying Requirements: Laying temperature ≥ 0℃; minimum bending radius = 15 × cable outer diameter |
| Technical Standards: |
| GB/T12706.1-2020 |
Model: VLV-0.6/1kV 4x120+1x70
| Product Parameters: |
|
Rated Voltage: 0.6/1 kV Conductor Material: Aluminum conductor (stranded) Conductor Cross-Section: 4 cores × 120 mm² + 1 core × 70 mm² Insulation Material: Polyvinyl chloride (PVC) Insulation Thickness: 1.6 mm for 120 mm² cores; 1.4 mm for 70 mm² core Sheath Material: Polyvinyl chloride (PVC) Sheath Thickness: 2.3 mm Temperature Resistance Range: -20℃ to 70℃ (normal operation) Short-Circuit Withstand Temperature: 160℃ (maximum duration ≤ 5 seconds) Laying Requirements: Laying temperature ≥ 0℃; minimum bending radius = 15 × cable outer diameter |
| Technical Standards: |
| GB/T12706.1-2020 |
Model: VV-0.6/1kV 3x95+1x50
| Product Parameters: |
|
Rated Voltage: 0.6/1KV Conductor Material: Copper conductor (single-core) Conductor Cross-Section: 3 cores 4mm² + 1 core 2.5mm² Insulation Material: Polyvinyl chloride (PVC) Insulation Thickness: 1.0mm for 4mm² cores; 0.8mm for 2.5mm² core Sheath Material: Polyvinyl chloride (PVC) Sheath Thickness: 1.8mm Temperature Resistance Range: Normal operation -20℃ to 70℃ Short-Circuit Withstand Temperature: 160℃ (maximum duration not exceeding 5 seconds) Laying Requirements: Laying temperature ≥ 0℃; minimum bending radius is 12 times the cable outer diameter |
| Technical Standards: |
| GB/T12706.1-2020 |