XLPE insulated power cable refers to a power cable that uses cross-linked polyethylene as the insulation layer. This material has significantly improved its heat resistance and mechanical strength through cross-linking technology. Its long-term allowable working temperature can reach 90 ° C, and it has excellent electrical performance, aging resistance, and current carrying capacity. It has a lightweight structure, easy installation, and does not contain oil, avoiding the problem of oil immersed paper insulated cables flowing. Therefore, it has become the absolute mainstay of medium and low voltage transmission and distribution systems, widely used in urban power grids, industrial and mining enterprises, building interiors, and various direct burial and tunnel laying occasions.

Model: YJLV22-8.7/15kV 3x150

 

Product Parameters:

Rated Voltage: 8.7/15kV

Conductor Material: Stranded Copper Conductor

Conductor Cross-Section: 1 Core 150mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 4.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 1.9mm

Operating Temperature: -40℃ ~ +90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 20D (20 times the cable outer diameter)

Technical Standards:
GB/T12706.2-2020

 

Model: YJLV22-8.7/15kV 3x240

 

Product Parameters:

Rated Voltage: 8.7/15kV

Conductor Material: Stranded Aluminum Conductor

Conductor Cross-Section: 3 Cores 240mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 4.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 3.4mm

Operating Temperature: -40℃ ~ +90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 12D (12 times the cable outer diameter)

Technical Standards:
GB/T12706.2-2020

 

Model: YJLV22-8.7/15kV 3x50

 

Product Parameters:

Rated Voltage: 8.7/15kV

Conductor Material: Aluminum conductor (stranded)

Conductor Cross-Section: 3-core 50mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 4.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 2.7mm

Operating Temperature: -40℃~+90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 12D

Technical Standards:
GB/T12706.2-2020

 

Model: YJV22-8.7/15kV 3x300

 

Product Parameters:

Rated Voltage: 8.7/15kV

Conductor Material: Copper conductor (stranded)

Conductor Cross-Section: 3-core 300mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 4.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 3.6mm

Operating Temperature: -40℃~+90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 12D

Technical Standards:
GB/T12706.2-2020

 

Model: YJLV62-26/35kV 1X185

 

Product Parameters:

Rated Voltage: 26/35kV

Conductor Material: Stranded Aluminum Conductor

Conductor Cross-Section: 1 Core 185mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 10.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 2.5mm

Operating Temperature: -40℃ ~ +90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 15D (15 times the cable outer diameter)

Technical Standards:
GB/T12706.3-2020

 

Model: YJV32-26/35kV 3X400

 

Product Parameters:

Rated Voltage: 26/35kV

Conductor Material: Stranded Copper Conductor

Conductor Cross-Section: 3 Cores 400mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 10.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 4.8mm

Operating Temperature: -40℃ ~ +90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 12D (12 times the cable outer diameter)

Technical Standards:
GB/T12706.3-2020

 

Model: YJV22-26/35kV 3x95

 

Product Parameters:

Rated Voltage: 26/35kV

Conductor Material: Copper conductor (stranded)

Conductor Cross-Section: 3-core 95mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 10.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 3.9mm

Operating Temperature: -40℃~+90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 12D

Technical Standards:
GB/T12706.3-2020

 

Model: YJLV22-26/35kV 3X630

 

Product Parameters:

Rated Voltage: 26/35kV

Conductor Material: Aluminum conductor (stranded)

Conductor Cross-Section: 3-core 630mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 10.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 5.8mm

Operating Temperature: -40℃~+90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 12D

Technical Standards:
GB/T12706.3-2020

 

Model: YJV22-26/35kV 3X400

 

Product Parameters:

Rated Voltage: 26/35kV

Conductor Material: Aluminum conductor (stranded)

Conductor Cross-Section: 3-core 630mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 10.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 5.8mm

Operating Temperature: -40℃~+90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 12D

Technical Standards:
GB/T12706.3-2020

Model: YJV22-26/35kV 3X120

 

Product Parameters:

Rated Voltage: 26/35kV

Conductor Material: Copper conductor (stranded)

Conductor Cross-Section: 3-core 120mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 10.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 4.0mm

Operating Temperature: -40℃~+90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 12D

Technical Standards:
GB/T12706.3-2020

 

  • toolbar
    sanyangylxl1982@163.com
  • toolbar
    +86-0319-5813666
  • toolbar
    toolbar
  • toolbar
    toolbar
  • toolbar