Contact Us
XLPE insulated power cable refers to a power cable that uses cross-linked polyethylene as the insulation layer. This material has significantly improved its heat resistance and mechanical strength through cross-linking technology. Its long-term allowable working temperature can reach 90 ° C, and it has excellent electrical performance, aging resistance, and current carrying capacity. It has a lightweight structure, easy installation, and does not contain oil, avoiding the problem of oil immersed paper insulated cables flowing. Therefore, it has become the absolute mainstay of medium and low voltage transmission and distribution systems, widely used in urban power grids, industrial and mining enterprises, building interiors, and various direct burial and tunnel laying occasions.
Model: YJLV22-8.7/15kV 3x150
| Product Parameters: |
|
Rated Voltage: 8.7/15kV Conductor Material: Stranded Copper Conductor Conductor Cross-Section: 1 Core 150mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 4.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 1.9mm Operating Temperature: -40℃ ~ +90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 20D (20 times the cable outer diameter) |
| Technical Standards: |
| GB/T12706.2-2020 |
Model: YJLV22-8.7/15kV 3x240
| Product Parameters: |
|
Rated Voltage: 8.7/15kV Conductor Material: Stranded Aluminum Conductor Conductor Cross-Section: 3 Cores 240mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 4.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 3.4mm Operating Temperature: -40℃ ~ +90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 12D (12 times the cable outer diameter) |
| Technical Standards: |
| GB/T12706.2-2020 |
Model: YJLV22-8.7/15kV 3x50
| Product Parameters: |
|
Rated Voltage: 8.7/15kV Conductor Material: Aluminum conductor (stranded) Conductor Cross-Section: 3-core 50mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 4.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 2.7mm Operating Temperature: -40℃~+90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 12D |
| Technical Standards: |
| GB/T12706.2-2020 |
Model: YJV22-8.7/15kV 3x300
| Product Parameters: |
|
Rated Voltage: 8.7/15kV Conductor Material: Copper conductor (stranded) Conductor Cross-Section: 3-core 300mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 4.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 3.6mm Operating Temperature: -40℃~+90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 12D |
| Technical Standards: |
| GB/T12706.2-2020 |
Model: YJLV62-26/35kV 1X185
| Product Parameters: |
|
Rated Voltage: 26/35kV Conductor Material: Stranded Aluminum Conductor Conductor Cross-Section: 1 Core 185mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 10.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 2.5mm Operating Temperature: -40℃ ~ +90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 15D (15 times the cable outer diameter) |
| Technical Standards: |
| GB/T12706.3-2020 |
Model: YJV32-26/35kV 3X400
| Product Parameters: |
|
Rated Voltage: 26/35kV Conductor Material: Stranded Copper Conductor Conductor Cross-Section: 3 Cores 400mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 10.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 4.8mm Operating Temperature: -40℃ ~ +90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 12D (12 times the cable outer diameter) |
| Technical Standards: |
| GB/T12706.3-2020 |
Model: YJV22-26/35kV 3x95
| Product Parameters: |
|
Rated Voltage: 26/35kV Conductor Material: Copper conductor (stranded) Conductor Cross-Section: 3-core 95mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 10.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 3.9mm Operating Temperature: -40℃~+90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 12D |
| Technical Standards: |
| GB/T12706.3-2020 |
Model: YJLV22-26/35kV 3X630
| Product Parameters: |
|
Rated Voltage: 26/35kV Conductor Material: Aluminum conductor (stranded) Conductor Cross-Section: 3-core 630mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 10.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 5.8mm Operating Temperature: -40℃~+90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 12D |
| Technical Standards: |
| GB/T12706.3-2020 |
Model: YJV22-26/35kV 3X400
| Product Parameters: |
|
Rated Voltage: 26/35kV Conductor Material: Aluminum conductor (stranded) Conductor Cross-Section: 3-core 630mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 10.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 5.8mm Operating Temperature: -40℃~+90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 12D |
| Technical Standards: |
| GB/T12706.3-2020 |
Model: YJV22-26/35kV 3X120
| Product Parameters: |
|
Rated Voltage: 26/35kV Conductor Material: Copper conductor (stranded) Conductor Cross-Section: 3-core 120mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 10.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 4.0mm Operating Temperature: -40℃~+90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 12D |
| Technical Standards: |
| GB/T12706.3-2020 |