Single-Core 4mm² Copper Conductor XLPE Insulated PV Cable
Model: PV1-F-0.6/1kv 1X4
| Product Parameters: |
|
Rated Voltage: 0.6/1kV Conductor Material: Copper Conductor (Single Core) Conductor Cross-Section: 1 Core 4mm² Insulation Material: 125℃Irradiated Cross-Linked Low-Smoke Halogen-Free Flame-Retardant Polyolefin Insulation Thickness: 0.7mm Sheath Material: 125℃Irradiated Cross-Linked Low-Smoke Halogen-Free Flame-Retardant Polyolefin Sheath Thickness: 0.8mm Temperature Resistance Range: Normal operating temperature -40℃to 90℃; withstands 250℃ during short circuits (maximum duration 5 seconds) Installation Requirements: Ambient temperature ≥ -20℃; minimum bending radius not less than 10 times the cable outer diameter (static installation) or 12 times (dynamic installation) |
| Technical Standards: |
| 2Pfg1169-2007 |
Application Scenario:
Mainly used for DC-side connections in photovoltaic (PV) power generation systems, including:
- Series connection between PV modules to realize power collection.
- Parallel connection between module strings and DC combiner boxes (distribution boxes) for centralized current output.
- Power supply lines from DC combiner boxes to inverters, transmitting raw DC power for subsequent energy conversion.
| Differences Between Ordinary Cables and PV Cables | |||||
| Performance | Ordinary Cables | PV Cables | |||
| Conductor | Copper or tinned copper conductor | Copper or tinned copper conductor | |||
| Insulation | PVC or XLPE insulation | Irradiated cross-linked polyolefin insulation | |||
| Sheath | PVC sheath | Irradiated cross-linked polyolefin sheath | |||
| Analysis: | |||||
| As shown in Table 1, the conductors used in ordinary cables are the same as those in PV cables. | |||||
| From Table 1, the insulation and sheath materials of ordinary cables differ from those of PV cables. | |||||
| Ordinary cables are only suitable for installation in general environments. | |||||
| Advantages of PV cables: High temperature resistance, low temperature resistance, oil resistance, acid-alkali-salt resistance, UV resistance, flame retardancy, and environmental friendliness. PV power cables are mainly used in harsh climatic conditions with a service life of over 25 years. | |||||
| PV Applications: | |||||
| The halogen-free PV1-F cable for solar photovoltaic power generation equipment is designed based on the special environmental conditions of photovoltaic installations. It is mainly suitable for DC voltage terminals, outgoing connections of power generation equipment, and busbar connections between modules. It is applicable to photovoltaic power generation systems with a maximum DC voltage of 1.8kV, and can be used in deserts with large day-night temperature differences, coastal areas with salt spray and humidity, and plateau areas with strong radiation. | |||||
| Specifications and Parameters: | |||||
| Nominal Conductor Cross-Section (mm²) | Structure | Specified Insulation Thickness (mm) | Specified Sheath Thickness (mm) | Theoretical Outer Diameter (mm) | Maximum DC Resistance at 20℃ (Ω/km) |
| 1.5 | 30/0.25 | 0.8 | 0.8 | 5.4±0.15 | 13.7 |
| 2.5 | 49/0.25 | 0.8 | 0.8 | 5.45±0.15 | 8.21 |
| 4 | 56/0.3 | 0.8 | 0.8 | 6.0±0.20 | 5.09 |
| 6 | 84/0.3 | 0.8 | 0.8 | 7.0±0.20 | 3.39 |
| 10 | 80/0.4 | 0.8 | 0.8 | 7.8±0.25 | 1.95 |
|
Notes: The above values are for reference only. Specific values shall be subject to the specification approval sheet or technical agreement. |
|||||