The enterprise specializes in producing a full range of wires and cables, including cross-linked power cables (flame-retardant/fire-resistant/low smoke halogen-free), plastic cables, photovoltaic cables, overhead insulated cables, mining cables, prefabricated branch cables, computer shielded control cables, fluoroplastic high-temperature resistant cables, fire-resistant cables, etc., fully meeting the needs of multiple fields such as power, energy, transportation, communication, industry, and high-tech. We have absolute strength in the manufacturing of cables of 35KV and below.

Model: VV-0.6/1kV 3x95+1x50

 

Product Parameters:

Rated Voltage: 0.6/1 kV

Conductor Material: Copper conductor (stranded)

Conductor Cross-Section: 3 cores × 95 mm² + 1 core × 50 mm²

Insulation Material: Polyvinyl chloride (PVC)

Insulation Thickness: 1.6 mm for 95 mm² cores; 1.4 mm for 50 mm² core

Sheath Material: Polyvinyl chloride (PVC)

Sheath Thickness: 2.2 mm

Temperature Resistance Range: -20℃ to 70℃ (normal operation)

Short-Circuit Withstand Temperature: 160℃ (maximum duration ≤ 5 seconds)

Laying Requirements: Laying temperature ≥ 0℃; minimum bending radius = 15 × cable outer diameter

Technical Standards:
GB/T12706.1-2020

 

Model: VLV-0.6/1kV 4x120+1x70

 

Product Parameters:

Rated Voltage: 0.6/1 kV

Conductor Material: Aluminum conductor (stranded)

Conductor Cross-Section: 4 cores × 120 mm² + 1 core × 70 mm²

Insulation Material: Polyvinyl chloride (PVC)

Insulation Thickness: 1.6 mm for 120 mm² cores; 1.4 mm for 70 mm² core

Sheath Material: Polyvinyl chloride (PVC)

Sheath Thickness: 2.3 mm

Temperature Resistance Range: -20℃ to 70℃ (normal operation)

Short-Circuit Withstand Temperature: 160℃ (maximum duration ≤ 5 seconds)

Laying Requirements: Laying temperature ≥ 0℃; minimum bending radius = 15 × cable outer diameter

Technical Standards:
GB/T12706.1-2020

 

Model: VV-0.6/1kV 3x95+1x50

 

Product Parameters:

Rated Voltage: 0.6/1KV

Conductor Material: Copper conductor (single-core)

Conductor Cross-Section: 3 cores 4mm² + 1 core 2.5mm²

Insulation Material: Polyvinyl chloride (PVC)

Insulation Thickness: 1.0mm for 4mm² cores; 0.8mm for 2.5mm² core

Sheath Material: Polyvinyl chloride (PVC)

Sheath Thickness: 1.8mm

Temperature Resistance Range: Normal operation -20℃ to 70℃

Short-Circuit Withstand Temperature: 160℃ (maximum duration not exceeding 5 seconds)

Laying Requirements: Laying temperature ≥ 0℃; minimum bending radius is 12 times the cable outer diameter

Technical Standards:
GB/T12706.1-2020

 

Model: YJLV-0.6/1kV 4x95+1x50

 

Product Parameters:

Rated Voltage:0.6/1KV

Conductor Material:Aluminum Conductor (Stranded)

Conductor Cross-section:4 Cores 95mm² + 1 Core 50mm²

Insulation Material:Irradiated Cross-linked Polyethylene (XLPE)

Insulation Thickness:95mm² Core: 1.1mm; 50mm² Core: 1.0mm

Sheath Material:Polyvinyl Chloride (PVC)

Sheath Thickness:2.2mm

Operating Temperature:-40℃~+90℃

Short-circuit Withstand Temperature:250℃

Minimum Laying Temperature:0℃

Bending Radius:15D

Technical Standards:
GB/T12706.1-2020

 

Model: YJLV-0.6/1kV 3x95+1x50

 

Product Parameters:

Rated Voltage: 0.6/1kV

Conductor Material: Stranded Aluminum Conductor

Conductor Cross-Section: 3 Cores 95mm² + 1 Core 50mm²

Insulation Material: Irradiated Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 1.1mm (for 95mm² cores); 1.0mm (for 50mm² core)

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 2.1mm

Operating Temperature: -40℃ ~ +90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 15D (15 times the cable outer diameter)

Technical Standards:
GB/T12706.1-2020

 

Model: YJLV-0.6/1kV 3x240+2x120

 

Product Parameters:

Rated Voltage: 0.6/1kV

Conductor Material: Stranded Aluminum Conductor

Conductor Cross-Section: 3 Cores 240mm² + 2 Cores 120mm²

Insulation Material: Irradiated Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 1.7mm (for 240mm² cores); 1.2mm (for 120mm² cores)

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 2.7mm

Operating Temperature: -40℃ ~ +90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 15D (15 times the cable outer diameter)

Technical Standards:
GB/T12706.1-2020

 

Model: YJLV-0.6/1kV 4x150+1x70

 

Product Parameters:

Rated Voltage: 0.6/1kV

Conductor Material: Stranded Aluminum Conductor

Conductor Cross-Section: 4 Cores 150mm² + 1 Core 70mm²

Insulation Material: Irradiated Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 1.4mm (for 150mm² cores); 1.1mm (for 70mm² core)

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 2.5mm

Operating Temperature: -40℃ ~ +90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 15D (15 times the cable outer diameter)

Technical Standards:
GB/T12706.1-2020

 

Model: YJV22-0.6/1kV 3x120+2x70

 

Product Parameters:

Rated Voltage: 0.6/1kV

Conductor Material: Stranded Copper Conductor

Conductor Cross-Section: 3 Cores 120mm² + 2 Cores 70mm²

Insulation Material: Irradiated Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 1.2mm (for 120mm² cores); 1.1mm (for 70mm² cores)

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 2.4mm

Operating Temperature: -40℃ ~ +90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 12D (12 times the cable outer diameter)

Technical Standards:
GB/T12706.1-2020

 

Model: YJV22-0.6/1kV 3x240+1x120

 

Product Parameters:

Rated Voltage: 0.6/1kV

Conductor Material: Stranded Copper Conductor

Conductor Cross-Section: 3 Cores 240mm² + 1 Core 120mm²

Insulation Material: Irradiated Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 1.7mm (for 240mm² cores); 1.2mm (for 120mm² core)

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 2.8mm

Operating Temperature: -40℃ ~ +90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 12D (12 times the cable outer diameter)

Technical Standards:
GB/T12706.1-2020

 

Model: YJV-0.6/1kV 4x25+1x16

 

Product Parameters:

Rated Voltage: 0.6/1kV

Conductor Material: Stranded Copper Conductor

Conductor Cross-Section: 4 Cores 25mm² + 1 Core 16mm²

Insulation Material: Irradiated Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 0.9mm (for 25mm² cores); 0.7mm (for 16mm² core)

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 1.8mm

Operating Temperature: -40℃ ~ +90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 15D (15 times the cable outer diameter)

Technical Standards:
GB/T12706.1-2020

 