Contact Us
The enterprise specializes in producing a full range of wires and cables, including cross-linked power cables (flame-retardant/fire-resistant/low smoke halogen-free), plastic cables, photovoltaic cables, overhead insulated cables, mining cables, prefabricated branch cables, computer shielded control cables, fluoroplastic high-temperature resistant cables, fire-resistant cables, etc., fully meeting the needs of multiple fields such as power, energy, transportation, communication, industry, and high-tech. We have absolute strength in the manufacturing of cables of 35KV and below.
Model: JKLYJ-1kV 1X240
| Product Parameters: |
|
Rated Voltage: 1 kV Conductor Material: Aluminum conductor (stranded) Conductor Cross-Section: 1 core × 240 mm² Insulation Material: Silane cross-linked polyethylene (XLPE) Insulation Thickness: 2.2 mm Temperature Resistance Range: Normal operating temperature: -40℃to 90℃; withstands 250℃ during short circuits (maximum duration: 5 seconds) Laying Requirements: Suitable only for outdoor aerial installation. During erection, safety distances from the ground, buildings, and trees must be maintained (e.g., minimum distance of 6 meters from the ground in residential areas), and the parallel laying spacing between cables shall not be less than 0.1 meters. |
| Technical Standards: |
| GB/T12527-2008 |
Model: JKLYJ-1kV 1X400
| Product Parameters: |
|
Rated Voltage: 1 kV Conductor Material: Aluminum conductor (stranded) Conductor Cross-Section: 1 core × 400 mm² Insulation Material: Silane cross-linked polyethylene (XLPE) Insulation Thickness: 2.2 mm Temperature Resistance Range: Conductor temperature ≤ 90℃for long-term operation; ≤ 250℃ for short circuits (≤ 5 seconds); adaptable to outdoor environments of -40℃ ~ 40℃ Laying Requirements: Must comply with outdoor aerial cable installation specifications |
| Technical Standards: |
| GB/T12527-2008 |
Model: KVV-450/750V 24X1.5
| Product Parameters: |
|
Rated Voltage: 450/750 V Conductor Material: Copper conductor (single-core) Conductor Cross-Section: 1.5 mm² Insulation Material: Polyvinyl chloride (PVC) Insulation Thickness: 0.7 mm Sheath Material: Polyvinyl chloride (PVC) Sheath Thickness: 1.7 mm Temperature Resistance Range: Long-term operation ≤ 70℃; short circuit (≤5 seconds) ≤ 160℃; ambient temperature -15℃ ~ 40℃ Laying Requirements: Fixed installation indoors, in cable trenches, or pipelines. Avoid direct exposure to high temperatures and oil contamination. Minimum bending radius ≥ 10 × cable outer diameter. |
| Technical Standards: |
| GB/T9330-2020 |
Model: KVV22-450/750V-14X2.5
| Product Parameters: |
|
Rated Voltage: 450/750 V Conductor Material: Copper conductor (single-core) Conductor Cross-Section: 2.5 mm² Insulation Material: Polyvinyl chloride (PVC) Insulation Thickness: 0.8 mm Sheath Material: Polyvinyl chloride (PVC) Sheath Thickness: 1.7 mm Temperature Resistance Range: Long-term operation ≤ 70℃; short circuit (≤5 seconds) ≤ 160℃; ambient temperature -15℃ ~ 40℃ Laying Requirements: Suitable for indoor/cable trench/direct burial installation. Avoid high temperatures and oil contamination. Minimum bending radius ≥ 12 × cable outer diameter. Anti-corrosion treatment required for direct burial. |
| Technical Standards: |
| GB/T9330-2020 |
Model: YJLHVS2-0.6/1kV 4X150+1X70
| Product Parameters: |
|
Rated Voltage: 0.6/1 kV Conductor Material: Aluminum alloy conductor (stranded) Conductor Cross-Section: 4 cores × 150 mm² + 1 core × 70 mm² Insulation Material: Irradiated cross-linked polyethylene (XLPE) Insulation Thickness: 1.4 mm for 150 mm² cores; 1.1 mm for 70 mm² core Sheath Material: Polyvinyl chloride (PVC) Sheath Thickness: 2.5 mm Temperature Resistance Range: Long-term operation ≤ 90℃; short circuit (≤5 seconds) ≤ 250℃; ambient temperature -40℃ ~ 40℃ Laying Requirements: Suitable for indoor/cable trench/direct burial installation. Avoid high temperature and corrosive environments. Minimum bending radius ≥ 15 × cable outer diameter. Anti-corrosion treatment required for direct burial. |
| Technical Standards: |
| GB/T31840.1-2015 |
Model: YC-450/750V 3X70
| Product Parameters: |
|
Rated Voltage: 450/750 V Conductor Material: Copper conductor (stranded) Conductor Cross-Section: 3 cores × 70 mm² Insulation Material: Rubber insulation Insulation Thickness: 1.6 mm Sheath Material: Rubber sheath Sheath Thickness: 4.8 mm Temperature Resistance Range: Long-term operation ≤ 60℃; short circuit (≤5 seconds) ≤ 160℃; ambient temperature -30℃ ~ 60℃; resistant to short-term high temperature and oil contamination Laying Requirements: Suitable for mobile or fixed installation. Avoid direct sunlight and sharp scratches. Minimum bending radius ≥ 6 × cable outer diameter. Do not over-bend. |
| Technical Standards: |
| JB/T8735.2-2016 |
Model: YC-450/750V 3X16+1X10
| Product Parameters: |
|
Rated Voltage: 450/750 V Conductor Material: Copper conductor (stranded) Conductor Cross-Section: 3 cores × 16 mm² + 1 core × 10 mm² Insulation Material: Rubber insulation Insulation Thickness: 1.2 mm (for both 16 mm² and 10 mm² conductors) Sheath Material: Rubber sheath Sheath Thickness: 3.5 mm Temperature Resistance Range: Long-term allowable operating temperature of conductors ≤ 60℃ Laying Requirements: Suitable for mobile or fixed installation. Minimum bending radius ≥ 6 × cable outer diameter. Avoid sharp scratches and excessive bending. |
| Technical Standards: |
|
JB/T8735.2-2016 |