The enterprise specializes in producing a full range of wires and cables, including cross-linked power cables (flame-retardant/fire-resistant/low smoke halogen-free), plastic cables, photovoltaic cables, overhead insulated cables, mining cables, prefabricated branch cables, computer shielded control cables, fluoroplastic high-temperature resistant cables, fire-resistant cables, etc., fully meeting the needs of multiple fields such as power, energy, transportation, communication, industry, and high-tech. We have absolute strength in the manufacturing of cables of 35KV and below.
Model: YJLV22-26/35kV 3X630
| Product Parameters: |
|
Rated Voltage: 26/35kV Conductor Material: Aluminum conductor (stranded) Conductor Cross-Section: 3-core 630mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 10.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 5.8mm Operating Temperature: -40℃~+90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 12D |
| Technical Standards: |
| GB/T12706.3-2020 |
Model: YJV22-26/35kV 3X400
| Product Parameters: |
|
Rated Voltage: 26/35kV Conductor Material: Aluminum conductor (stranded) Conductor Cross-Section: 3-core 630mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 10.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 5.8mm Operating Temperature: -40℃~+90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 12D |
| Technical Standards: |
| GB/T12706.3-2020 |
Model: YJV22-26/35kV 3X120
| Product Parameters: |
|
Rated Voltage: 26/35kV Conductor Material: Copper conductor (stranded) Conductor Cross-Section: 3-core 120mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 10.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 4.0mm Operating Temperature: -40℃~+90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 12D |
| Technical Standards: |
| GB/T12706.3-2020 |
Model: BVR-450/750V 10
| Product Parameters: |
|
Rated Voltage: 450/750V Conductor Material: Stranded Copper Conductor Conductor Cross-Section: 1 Core 10mm² Insulation Material: Polyvinyl Chloride (PVC) Insulation Thickness: 1.0mm Temperature Resistance Range: Normal operating temperature -20℃to 70℃; withstands 160℃ for short circuits (maximum duration 5 seconds) Installation Requirements: Ambient temperature ≥ 0℃; minimum bending radius not less than 6 times the cable outer diameter (for single core) |
| Technical Standards: |
| JB/T8734.2-2016 |
Model: BV-450/750V 2.5
| Product Parameters: |
|
Rated Voltage: 450/750V Conductor Material: Copper Conductor (Single Core) Conductor Cross-Section: 1 Core 2.5mm² Insulation Material: Polyvinyl Chloride (PVC) Insulation Thickness: 0.8mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 2.2mm Temperature Resistance Range: Normal operating temperature -20℃to 70℃; withstands 160℃ during short circuits (maximum duration 5 seconds) Installation Requirements: Ambient temperature ≥ 0℃; minimum bending radius not less than 6 times the cable outer diameter (for single core) |
| Technical Standards: |
| GB/T5023.3-2008 |
Model: PV1-F-0.6/1kv 1X4
| Product Parameters: |
|
Rated Voltage: 0.6/1kV Conductor Material: Copper Conductor (Single Core) Conductor Cross-Section: 1 Core 4mm² Insulation Material: 125℃Irradiated Cross-Linked Low-Smoke Halogen-Free Flame-Retardant Polyolefin Insulation Thickness: 0.7mm Sheath Material: 125℃Irradiated Cross-Linked Low-Smoke Halogen-Free Flame-Retardant Polyolefin Sheath Thickness: 0.8mm Temperature Resistance Range: Normal operating temperature -40℃to 90℃; withstands 250℃ during short circuits (maximum duration 5 seconds) Installation Requirements: Ambient temperature ≥ -20℃; minimum bending radius not less than 10 times the cable outer diameter (static installation) or 12 times (dynamic installation) |
| Technical Standards: |
| 2Pfg1169-2007 |
Model: JKLGYJ-10kV 185-25
| Product Parameters: |
|
Rated Voltage: 10 kV Conductor Material: Aluminum conductor (stranded) with steel core Conductor Cross-Section: Aluminum 185 mm² / Steel core 25 mm² Insulation Material: Silane cross-linked polyethylene (XLPE) Insulation Thickness: 3.4 mm Temperature Resistance Range: Conductor temperature ≤ 90℃for long-term operation; ≤ 250℃ for short circuits (≤ 5 seconds); adaptable to outdoor environments of -40℃ ~ 40℃ Laying Requirements: Complies with 10 kV aerial cable specifications. Avoid high-temperature and corrosive areas. Minimum bending radius ≥ 20 × cable outer diameter. Use dedicated insulated clamps for outdoor fixation; leverage the steel core's properties to ensure erection stability. |
| Technical Standards: |
| GB/T14049-2008 |
Model: JKLYJ-10kV 1X50
| Product Parameters: |
|
Rated Voltage: 10 kV Conductor Material: Aluminum conductor (stranded) Conductor Cross-Section: 1 core × 50 mm² Insulation Material: Silane cross-linked polyethylene (XLPE) Insulation Thickness: 3.4 mm Temperature Resistance Range: Normal operating temperature -40℃to 90℃; withstands 250℃ for short circuits (maximum duration 5 seconds) Laying Requirements: The bending radius of the cable shall not be less than 12 times the cable outer diameter. |
| Technical Standards: |
| GB/T14049-2008 |
Model: JKLYJ-10kV 1X300
| Product Parameters: |
|
Rated Voltage: 10 kV Conductor Material: Aluminum conductor (stranded) Conductor Cross-Section: 1 core × 300 mm² Insulation Material: Silane cross-linked polyethylene (XLPE) Insulation Thickness: 3.4 mm Temperature Resistance Range: Long-term operation ≤ 90℃; short circuit (≤5 seconds) ≤ 250℃; outdoor adaptation range -40℃ ~ 40℃ Laying Requirements: Complies with 10 kV aerial cable standards. Avoid high-temperature and corrosive environments. Minimum bending radius ≥ 20 × cable outer diameter. Use dedicated insulated clamps. |
| Technical Standards: |
| GB/T14049-2008 |
Model: JKLYJ-10kV 1X240
| Product Parameters: |
|
Rated Voltage: 10 kV Conductor Material: Aluminum conductor (stranded) Conductor Cross-Section: 1 core × 240 mm² Insulation Material: Silane cross-linked polyethylene (XLPE) Insulation Thickness: 3.4 mm Temperature Resistance Range: Conductor temperature ≤ 90℃for long-term operation; ≤ 250℃ for short circuits (≤ 5 seconds); outdoor ambient temperature adaptation range: -40℃ ~ 40℃ Laying Requirements: Complies with 10 kV aerial cable specifications. Avoid high-temperature and corrosive environments. Minimum bending radius ≥ 20 × cable outer diameter. Use dedicated insulated clamps for outdoor fixation. |
| Technical Standards: |
| GB/T14049-2008 |