Contact Us
The enterprise specializes in producing a full range of wires and cables, including cross-linked power cables (flame-retardant/fire-resistant/low smoke halogen-free), plastic cables, photovoltaic cables, overhead insulated cables, mining cables, prefabricated branch cables, computer shielded control cables, fluoroplastic high-temperature resistant cables, fire-resistant cables, etc., fully meeting the needs of multiple fields such as power, energy, transportation, communication, industry, and high-tech. We have absolute strength in the manufacturing of cables of 35KV and below.
Model: YJV-0.6/1kV 3x185+1x95
| Product Parameters: |
|
Rated Voltage: 0.6/1kV Conductor Material: Stranded Copper Conductor Conductor Cross-Section: 3 Cores 185mm² + 1 Core 95mm² Insulation Material: Irradiated Cross-Linked Polyethylene (XLPE) Insulation Thickness: 1.6mm (for 185mm² cores); 1.1mm (for 95mm² core) Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 2.5mm Operating Temperature: -40℃ ~ +90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 15D (15 times the cable outer diameter) |
| Technical Standards: |
| GB/T12706.1-2020 |
Model: YJLV22-0.6/1kV 3X185+1X95
| Product Parameters: |
|
Rated Voltage: 0.6/1kV Conductor Material: Stranded Aluminum Conductor Conductor Cross-Section: 3 Cores 185mm² + 1 Core 95mm² Insulation Material: Irradiated Cross-Linked Polyethylene (XLPE) Insulation Thickness: 1.6mm (for 185mm² cores); 1.1mm (for 95mm² core) Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 2.6mm Operating Temperature: -40℃ ~ +90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 12D (12 times the cable outer diameter) |
| Technical Standards: |
| GB/T12706.1-2020 |
Model: YJV-8.7/15kV 3x120
| Product Parameters: |
|
Rated Voltage: 8.7/15kV Conductor Material: Stranded Copper Conductor Conductor Cross-Section: 3 Cores 120mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 4.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 2.8mm Operating Temperature: -40℃ ~ +90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 15D (15 times the cable outer diameter) |
| Technical Standards: |
| GB/T12706.2-2020 |
Model: YJLV22-8.7/15kV 3x150
| Product Parameters: |
|
Rated Voltage: 8.7/15kV Conductor Material: Stranded Copper Conductor Conductor Cross-Section: 1 Core 150mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 4.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 1.9mm Operating Temperature: -40℃ ~ +90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 20D (20 times the cable outer diameter) |
| Technical Standards: |
| GB/T12706.2-2020 |
Model: YJLV22-8.7/15kV 3x240
| Product Parameters: |
|
Rated Voltage: 8.7/15kV Conductor Material: Stranded Aluminum Conductor Conductor Cross-Section: 3 Cores 240mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 4.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 3.4mm Operating Temperature: -40℃ ~ +90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 12D (12 times the cable outer diameter) |
| Technical Standards: |
| GB/T12706.2-2020 |
Model: YJLV22-8.7/15kV 3x50
| Product Parameters: |
|
Rated Voltage: 8.7/15kV Conductor Material: Aluminum conductor (stranded) Conductor Cross-Section: 3-core 50mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 4.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 2.7mm Operating Temperature: -40℃~+90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 12D |
| Technical Standards: |
| GB/T12706.2-2020 |
Model: YJV22-8.7/15kV 3x300
| Product Parameters: |
|
Rated Voltage: 8.7/15kV Conductor Material: Copper conductor (stranded) Conductor Cross-Section: 3-core 300mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 4.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 3.6mm Operating Temperature: -40℃~+90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 12D |
| Technical Standards: |
| GB/T12706.2-2020 |
Model: YJLV62-26/35kV 1X185
| Product Parameters: |
|
Rated Voltage: 26/35kV Conductor Material: Stranded Aluminum Conductor Conductor Cross-Section: 1 Core 185mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 10.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 2.5mm Operating Temperature: -40℃ ~ +90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 15D (15 times the cable outer diameter) |
| Technical Standards: |
| GB/T12706.3-2020 |
Model: YJV32-26/35kV 3X400
| Product Parameters: |
|
Rated Voltage: 26/35kV Conductor Material: Stranded Copper Conductor Conductor Cross-Section: 3 Cores 400mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 10.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 4.8mm Operating Temperature: -40℃ ~ +90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 12D (12 times the cable outer diameter) |
| Technical Standards: |
| GB/T12706.3-2020 |
Model: YJV22-26/35kV 3x95
| Product Parameters: |
|
Rated Voltage: 26/35kV Conductor Material: Copper conductor (stranded) Conductor Cross-Section: 3-core 95mm² Insulation Material: Cross-Linked Polyethylene (XLPE) Insulation Thickness: 10.3mm Sheath Material: Polyvinyl Chloride (PVC) Sheath Thickness: 3.9mm Operating Temperature: -40℃~+90℃ Short-Circuit Withstand Temperature: 250℃ Minimum Laying Temperature: 0℃ Bending Radius: 12D |
| Technical Standards: |
| GB/T12706.3-2020 |