The enterprise specializes in producing a full range of wires and cables, including cross-linked power cables (flame-retardant/fire-resistant/low smoke halogen-free), plastic cables, photovoltaic cables, overhead insulated cables, mining cables, prefabricated branch cables, computer shielded control cables, fluoroplastic high-temperature resistant cables, fire-resistant cables, etc., fully meeting the needs of multiple fields such as power, energy, transportation, communication, industry, and high-tech. We have absolute strength in the manufacturing of cables of 35KV and below.

Model: YJV-0.6/1kV 3x185+1x95

 

Product Parameters:

Rated Voltage: 0.6/1kV

Conductor Material: Stranded Copper Conductor

Conductor Cross-Section: 3 Cores 185mm² + 1 Core 95mm²

Insulation Material: Irradiated Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 1.6mm (for 185mm² cores); 1.1mm (for 95mm² core)

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 2.5mm

Operating Temperature: -40℃ ~ +90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 15D (15 times the cable outer diameter)

Technical Standards:
GB/T12706.1-2020

 

Model: YJLV22-0.6/1kV 3X185+1X95

 

Product Parameters:

Rated Voltage: 0.6/1kV

Conductor Material: Stranded Aluminum Conductor

Conductor Cross-Section: 3 Cores 185mm² + 1 Core 95mm²

Insulation Material: Irradiated Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 1.6mm (for 185mm² cores); 1.1mm (for 95mm² core)

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 2.6mm

Operating Temperature: -40℃ ~ +90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 12D (12 times the cable outer diameter)

Technical Standards:
GB/T12706.1-2020

 

Model: YJV-8.7/15kV 3x120

 

Product Parameters:

Rated Voltage: 8.7/15kV

Conductor Material: Stranded Copper Conductor

Conductor Cross-Section: 3 Cores 120mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 4.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 2.8mm

Operating Temperature: -40℃ ~ +90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 15D (15 times the cable outer diameter)

Technical Standards:
GB/T12706.2-2020

 

Model: YJLV22-8.7/15kV 3x150

 

Product Parameters:

Rated Voltage: 8.7/15kV

Conductor Material: Stranded Copper Conductor

Conductor Cross-Section: 1 Core 150mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 4.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 1.9mm

Operating Temperature: -40℃ ~ +90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 20D (20 times the cable outer diameter)

Technical Standards:
GB/T12706.2-2020

 

Model: YJLV22-8.7/15kV 3x240

 

Product Parameters:

Rated Voltage: 8.7/15kV

Conductor Material: Stranded Aluminum Conductor

Conductor Cross-Section: 3 Cores 240mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 4.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 3.4mm

Operating Temperature: -40℃ ~ +90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 12D (12 times the cable outer diameter)

Technical Standards:
GB/T12706.2-2020

 

Model: YJLV22-8.7/15kV 3x50

 

Product Parameters:

Rated Voltage: 8.7/15kV

Conductor Material: Aluminum conductor (stranded)

Conductor Cross-Section: 3-core 50mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 4.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 2.7mm

Operating Temperature: -40℃~+90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 12D

Technical Standards:
GB/T12706.2-2020

 

Model: YJV22-8.7/15kV 3x300

 

Product Parameters:

Rated Voltage: 8.7/15kV

Conductor Material: Copper conductor (stranded)

Conductor Cross-Section: 3-core 300mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 4.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 3.6mm

Operating Temperature: -40℃~+90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 12D

Technical Standards:
GB/T12706.2-2020

 

Model: YJLV62-26/35kV 1X185

 

Product Parameters:

Rated Voltage: 26/35kV

Conductor Material: Stranded Aluminum Conductor

Conductor Cross-Section: 1 Core 185mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 10.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 2.5mm

Operating Temperature: -40℃ ~ +90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 15D (15 times the cable outer diameter)

Technical Standards:
GB/T12706.3-2020

 

Model: YJV32-26/35kV 3X400

 

Product Parameters:

Rated Voltage: 26/35kV

Conductor Material: Stranded Copper Conductor

Conductor Cross-Section: 3 Cores 400mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 10.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 4.8mm

Operating Temperature: -40℃ ~ +90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 12D (12 times the cable outer diameter)

Technical Standards:
GB/T12706.3-2020

 

Model: YJV22-26/35kV 3x95

 

Product Parameters:

Rated Voltage: 26/35kV

Conductor Material: Copper conductor (stranded)

Conductor Cross-Section: 3-core 95mm²

Insulation Material: Cross-Linked Polyethylene (XLPE)

Insulation Thickness: 10.3mm

Sheath Material: Polyvinyl Chloride (PVC)

Sheath Thickness: 3.9mm

Operating Temperature: -40℃~+90℃

Short-Circuit Withstand Temperature: 250℃

Minimum Laying Temperature: 0℃

Bending Radius: 12D

Technical Standards:
GB/T12706.3-2020

 